баннер
Дом

Камера для испытаний на высокие и низкие температуры

Камера для испытаний на высокие и низкие температуры

  • Key Differences in Using Environmental Test Chambers Between Summer and Winter
    Nov 26, 2025
    The core difference lies in the impact of ambient temperature and humidity variations on equipment operating efficiency, energy consumption, and test accuracy. Targeted measures for temperature/humidity control, heat dissipation/anti-freezing, and maintenance are required. Specific differences and precautions are as follows: I. Core Difference Comparison Table Dimension Summer Operation Characteristics Winter Operation Characteristics Ambient Conditions High temperature & high humidity (room temp: 30-40℃, RH: 60%-90%) Low temperature & low humidity (room temp: 0-15℃, RH: 30%-60%) Equipment Load High refrigeration system load, prone to overload High heating system load; humidification compensation required for certain models (e.g., temperature-humidity chambers) Impact on Test Accuracy High humidity causes condensation, affecting sensor accuracy Low temperature leads to pipeline freezing; low humidity may reduce stability of humidity tests Energy Consumption High refrigeration energy consumption High heating/humidification energy consumption   II. Season-Specific Precautions (1) Summer Operation: Focus on High Temperature/High Humidity/Overload Prevention 1. Ambient Heat Dissipation Management Reserve ≥50cm ventilation space around the chamber; avoid direct sunlight or proximity to heat sources (e.g., workshop ovens, air conditioner outlets). Ensure laboratory air conditioning operates normally, maintaining room temperature at 25-30℃. If room temp exceeds 35℃, install industrial fans or cooling devices to assist heat dissipation and prevent refrigeration system overload protection triggered by high ambient temperatures. 2. Moisture & Condensation Control Regularly clean chamber door gaskets with a dry cloth to prevent sealant aging and air leakage caused by high humidity. After humidity tests, open the chamber door promptly for ventilation and wipe off condensation to avoid moisture damage to sensors (e.g., humidity sensors). 3. Equipment Operation Protection Avoid prolonged continuous operation of extreme low-temperature tests (e.g., below -40℃). Recommend shutting down for 1 hour after 8 hours of operation to protect the compressor. Periodically inspect refrigeration system radiators (condensers) and remove dust/debris (blow with compressed air monthly) to ensure heat dissipation efficiency. (2) Winter Operation: Focus on Anti-Freezing/Low Humidity/Startup Failure Prevention 1. Ambient Temperature Guarantee Maintain laboratory temperature above 5℃ (strictly follow 10℃ if specified as the minimum operating temperature) to prevent pipeline freezing (e.g., refrigeration capillaries, humidification pipes). For unheated laboratories, install an insulation cover (with ventilation holes reserved) or activate the "preheating mode" (if supported) before testing. 2. Humidification System Maintenance Use distilled water in the humidification tank to avoid pipe blockage from impurity crystallization at low temperatures. Drain water from the humidification tank and pipelines during long-term non-use to prevent freezing-induced component damage. 3. Startup & Operation Specifications In low-temperature environments, activate "standby mode" for 30 minutes preheating before setting test parameters to avoid compressor burnout from excessive startup load. If startup fails (e.g., compressor inactivity), check power voltage (prone to instability during winter peak hours) or contact after-sales to inspect pipeline freezing. 4. Low Humidity Compensation For low-humidity tests (e.g., ≤30% RH), winter dryness may cause rapid humidity. Adjust humidification frequency appropriately and use the "humidity calibration" function to reduce fluctuations. III. General Precautions (All Seasons) Calibrate temperature/humidity sensors quarterly to ensure data accuracy. Clean air filters monthly to maintain airflow circulation. Arrange test samples evenly to avoid blocking internal air ducts and ensure temperature/humidity uniformity. For long-term non-use: Run the chamber for 1 hour monthly in summer (moisture prevention) and drain pipeline water in winter (freezing prevention). By addressing seasonal environmental variations, equipment service life can be extended, and test failures caused by temperature/humidity fluctuations avoided—aligning with the high precision and stability requirements of the industrial test equipment industry.    
    ЧИТАТЬ ДАЛЕЕ
  • Differences Between High-Low Temperature Test Chamber and Thermal Shock Chamber
    Nov 26, 2025
    In industrial product reliability testing, high and low temperature test chambers and temperature shock test chambers are core environmental testing equipment, both simulating extreme temperatures to verify product durability. However, they differ fundamentally: the former focuses on gradual temperature-humidity cycles, while the latter on instantaneous thermal shock. Clarifying these differences is key to matching test needs and ensuring data validity. 1. Rate High-Low Temperature Test Chamber: Slow, with a regular rate of 0.7∼1 ℃/min, and rapid versions can reach 5∼15 ℃/min. Thermal Shock Chamber: Abrupt, with instant switching. 2. Structure High-Low Temperature Test Chamber: Single-chamber structure, integrating heating, refrigeration, and humidification functions. Thermal Shock Chamber: Multi-chamber structure, including high-temperature chamber, low-temperature chamber, and test chamber. 3. Temperature Continuity High-Low Temperature Test Chamber: The temperature changes smoothly without any "shock sensation". Thermal Shock Chamber: The temperature changes by leaps and bounds, with a common temperature range of −40∼150℃. 4. Application High-Low Temperature Test Chamber: Suitable for temperature endurance testing of general products such as electronic devices, household appliances, and building materials. Thermal Shock Chamber: Suitable for shock resistance testing of temperature-sensitive products such as automotive electronics, semiconductors, and aerospace components. 5. Core Position & Test Purpose High-Low Temperature Test Chamber: Simulates gradual temperature (and humidity) changes to test product stability under slow thermal variation (e.g., electronic devices’ performance after gradual cooling to -40℃ or heating to 85℃). Thermal Shock Chamber: Simulates abrupt temperature switching (≤30s transition) to test product resistance to extreme thermal shock (e.g., auto parts adapting to drastic day-night temperature changes, aerospace components’ tolerance to sudden high-low temperature shifts). Summary The high and low temperature test chamber is a "slow-paced endurance test", while the temperature shock chamber is a "fast-paced explosive power challenge". Just based on whether the product will encounter "sudden cold and heat" in the actual usage scenario, the precise selection can be made.
    ЧИТАТЬ ДАЛЕЕ
  • What should we pay attention to when using a thermal shock test chamber (water-cooled)?
    Nov 22, 2025
    I. Before Operation Use deionized water or distilled water as cooling water (to prevent scale formation); control temperature at 15-30℃, pressure at 0.15-0.3MPa, flow rate ≥5L/min. Clean the Y-type filter element in advance to ensure unobstructed water flow. Inspect water supply/drainage pipelines for secure connections, no leakage or kinking; keep drainage ports unobstructed with a height difference ≥10cm. Ensure the environment is ventilated and dry, grounding resistance ≤4Ω, and power supply (AC380V±10%) stable. Keep the inner chamber and shelves clean. Sample volume ≤1/3 of effective capacity, with weight evenly distributed on shelves. Seal moisture-sensitive parts of non-hermetic samples to avoid condensation affecting test accuracy. II. During Operation Real-time monitor cooling water pressure, flow rate and temperature. Immediately shut down for troubleshooting (pipeline blockage, leakage or chiller failure) if pressure drops sharply, flow is insufficient or temperature exceeds 35℃. Set high/low temperature parameters per GB/T, IEC and other standards (not exceeding rated range); control heating/cooling rate ≤5℃/min. Prohibit instantaneous switching between extreme temperatures. Do not open the door arbitrarily during operation (to prevent scalding/frostbite from hot/cold air). Use protective gloves for emergency sample handling. Shut down immediately for maintenance upon alarm (overtemperature, water shortage, etc.); prohibit forced operation. III. After Test Turn off power and cooling water inlet/outlet valves; drain residual water in pipelines. Clean the water tank and replace water monthly; add special water stabilizer to extend pipeline service life. Wipe the inner chamber and shelves after temperature returns to room temperature. Clean the air filter (1-2 times monthly); inspect pipeline seals and replace aging/leaking ones promptly. For long-term non-use: Power on and run for 30 minutes monthly (including water cooling system circulation), inject anti-rust protection fluid into pipelines, and cover the equipment with a dust cover in a dry, ventilated place. IV. Prohibitions Prohibit using unqualified water (tap water, well water, etc.) or blocking filters/drainage ports (to avoid affecting heat dissipation). Prohibit overloading samples or unauthorized disassembly/modification of water cooling pipelines/core components. Repairs must be performed by professionals. Prohibit frequent start-stop (wait ≥5 minutes after shutdown before restarting). Prohibit placing flammable, explosive or corrosive substances.
    ЧИТАТЬ ДАЛЕЕ
  • Differences between High and Low Temperature Test Chamber and Constant Temperature Test Chamber
    Nov 13, 2025
        In environmental reliability testing, high-low temperature humidity test chambers and constant temperature and humidity test chambers are easily confused due to similar names, but they differ significantly in testing capabilities, applications and technical characteristics. Accurate distinction and selection are key to ensuring valid test data. This blog will analyze the core differences and provide selection suggestions. I. Core Definition: Essential Distinction of Functional Boundaries     The core difference between the two starts with functional positioning, which directly determines the applicable scenarios.     The core of the constant temperature and humidity test chamber is "maintaining stability". It can accurately control and maintain the set temperature and humidity for a long time, and is used to simulate the long-term performance of products in specific environments, such as electronic component stability testing and textile temperature-humidity sensitivity testing. Its core requirement is "steady-state environmental performance verification".     The high-low temperature humidity test chamber focuses on "dynamic simulation". In addition to precise temperature and humidity control, it has a wide-range fluctuation capability, which can simulate environments such as high-low temperature cycles and alternating humidity and heat, such as extreme temperature differences during product transportation and diurnal temperature-humidity changes of outdoor equipment. Its core requirement is "dynamic environmental reliability verification". II. Key Differences: Multi-dimensional Analysis from Technology to Application 1. Temperature and Humidity Range and Fluctuation Capacity     The constant temperature and humidity chamber has a mild temperature and humidity range (temperature 0℃-100℃, humidity 30%-95%RH) and high control precision (temperature fluctuation ±0.5℃, humidity ±2%RH), but no extreme temperature-humidity impact capability.     The high-low temperature humidity chamber has a wider temperature and humidity coverage (temperature -70℃~200℃, humidity 10%-98%RH) and rapid change capability (heating rate 3℃/min-15℃/min, cooling rate 1℃/min-10℃/min), which can realize rapid cycle switching between "high temperature and high humidity - low temperature and low humidity"—a feature unavailable in the former. 2. Differences in Core Technical Architecture     The constant temperature and humidity chamber adopts single-stage compression refrigeration, conventional resistance heating, and steam or ultrasonic humidification. Its system design focuses on "energy saving and stability", with simple structure and low operating cost.     To meet extreme needs, the high-low temperature humidity chamber uses cascade refrigeration, rapid-heating tubes, and its humidity system includes a fast-response dehumidification module, with a thicker insulation layer on the chamber wall. Its technical complexity and manufacturing cost are much higher than the former. 3. Applicable Scenarios and Testing Purposes     The constant temperature and humidity chamber is used for steady-state environmental adaptability testing, such as electronic component aging and pharmaceutical storage simulation, to verify the performance consistency and durability of products in a fixed environment.     The high-low temperature humidity chamber focuses on dynamic reliability testing, such as high-low temperature cycling of auto parts and extreme environment simulation of aerospace products, to expose product defects (material aging, structural deformation, etc.) under drastic environmental changes.     In summary, the constant temperature and humidity chamber guards the steady-state environment, while the high-low temperature humidity chamber challenges the dynamic environment. There is no absolute advantage or disadvantage between the two. Only by matching needs, clarifying scenarios and budgets can the test truly guarantee product quality.
    ЧИТАТЬ ДАЛЕЕ
  • Lab Two-Chamber Thermal Shock Chamber
    Nov 03, 2025
    The two-chamber thermal shock chamber is a highly reliable environmental testing device specifically designed for evaluating the ability of products to withstand extreme temperature changes. It simulates harsh temperature shock conditions to rapidly expose the possible failures of materials, electronic components, automotive parts and aerospace equipment during rapid thermal expansion and contraction, such as cracking, performance degradation and connection faults. It is a key tool for improving product quality and reliability. The core design concept of this device lies in efficiency and harshness. It has two independently controlled test chambers inside: a high-temperature chamber and a low-temperature chamber, which are respectively maintained at the set extreme temperatures continuously. The sample to be tested is placed in an automatic mechanical basket. During the test, the basket will be rapidly switched between the high-temperature zone and the low-temperature zone under the program control, instantly exposing the sample to a huge temperature difference environment, thus achieving the true "thermal shock" effect. Compared with another mainstream three-chamber (static) impact chamber, the significant advantage of the two-chamber type lies in its extremely fast temperature conversion speed and short temperature recovery time, ensuring the strictness and consistency of the test conditions. It is highly suitable for testing samples with sturdy structures that can withstand mechanical movement, and the testing efficiency is extremely high. Its working principle determines that during the testing process, the temperature fluctuation of the high and low temperature chamber is small, it can quickly return to the set point, and is not significantly affected by the sample load. This equipment is widely used in fields such as semiconductors, integrated circuits, national defense science and technology, automotive electronics, and new material research and development, for conducting reliability tests as required by various international standards. Its main technical parameters include a wide temperature range (high temperatures up to +150°C to +200°C, low temperatures down to -40°C to -65°C or even lower), precise temperature control accuracy, and customizable sample area sizes. The Lab two-chamber thermal shock chamber, with its irreplaceable rapid temperature change capability, has become the ultimate touchstone for testing the adaptability and durability of products in extreme temperature environments, providing a strong guarantee for the precision manufacturing and reliability verification of modern industry.
    ЧИТАТЬ ДАЛЕЕ
  • Dragon Heat Flow Meter Temperature Control Test
    Oct 29, 2025
    Temperature control tests are usually conducted under two conditions: no-load (without sample placement) and load (with standard samples or actual samples being tested placed). The basic testing steps are as follows:   1. Preparatory work: Ensure that the heat flow meter has been fully preheated and is in a stable state. Prepare high-precision temperature sensors that have undergone metrological calibration (such as multiple platinum resistance PT100), and their accuracy should be much higher than the claimed indicators of the heat flow meter to be measured. 2. Temperature uniformity test: Multiple calibrated temperature sensors are arranged at different positions within the working area of the heat flow meter's heating plate (such as the center, four corners, edges, etc.). Set one or more typical test temperature points (such as -20°C, 25°C, 80°C). After the system reaches thermal stability, simultaneously record the temperature values of all sensors. Calculate the maximum, minimum and standard deviation of these readings to evaluate the uniformity. 3. Temperature control stability and accuracy test: Fix a calibrated temperature sensor at the center of the heating plate (or closely attach it to the built-in sensor of the instrument). Set the target temperature and start the temperature control. Record the entire process from the start to reaching the target temperature (for analyzing response speed and overshoot). After reaching the target temperature, continuously record for at least 1-2 hours (or as per standard requirements), with a sampling frequency high enough (such as once per second), and analyze the recorded data. 4. Load test: Place standard reference materials with known thermal physical properties or typical samples to be tested between the hot plates. Repeat step 3 and observe the changes in temperature control performance under load conditions. Load will directly affect the thermal inertia of the system, thereby influencing the response speed and stability.   When you are choosing or using a heat flow meter, be sure to carefully review the specific parameters regarding temperature control performance in its technical specification sheet and understand under what conditions (no-load/load) these parameters were measured. Lab will provide clear and verifiable temperature control test data and reports.
    ЧИТАТЬ ДАЛЕЕ
  • How is over-temperature protection carried out in a temperature test chamber?
    Oct 23, 2025
    The over-temperature protection of the temperature test chamber is a multi-level and multi-redundant safety system. Its core purpose is to prevent the temperature inside the chamber from rising out of control due to equipment failure, thereby protecting the safety of the test samples, the test chamber itself and the laboratory environment.   The protection system usually consists of the following key parts working together: 1. Sensor: The main sensor is used for the normal temperature control of the test chamber and provides feedback signals to the main controller. An independent over-temperature protection sensor is the key to a safety system. It is a temperature-sensing element independent of the main control temperature system (usually a platinum resistance or thermocouple), which is placed by strategically at the position within the box that best represents the risk of overheating (such as near the heater outlet or on the top of the working chamber). Its sole task is to monitor over-temperature. 2. Processing unit: The main controller receives signals from the main sensor and executes the set temperature program. The independent over-temperature protector, as an independent hardware device, is specifically designed to receive and process the signals from the over-temperature protection sensor. It does not rely on the main controller. Even if the main controller crashes or experiences a serious malfunction, it can still operate normally. 3. Actuator: The main controller controls the on and off of the heater and the cooler. The safety relay/solid-state relay receives the signal sent by the over-temperature protector and directly cuts off the power supply circuit of the heater. This is the final execution action.   The over-temperature protection of the temperature test chamber is a multi-level, hard-wire connected safety system designed based on the concepts of "redundancy" and "independence". It does not rely on the main control system. Through independent sensors and controllers, when a dangerous temperature is detected, it directly and forcibly cuts off the heating energy and notifies the user through sound and light alarms, thus forming a complete and reliable safety closed loop.
    ЧИТАТЬ ДАЛЕЕ
  • The Applicability of Temperature Test Chambers to the Testing of Household Environmental Products
    Oct 18, 2025
    A variety of products used in home environments (more common test objects) such as televisions, air conditioners, refrigerators, washing machines, smart speakers, routers, etc., as well as environmental protection products used to improve the home environment: such as air purifiers, fresh air systems, water purifiers, humidifiers/dehumidifiers, etc. No matter which category it is, as long as it needs to work stably for a long time in a home environment, it must undergo strict environmental reliability tests. The high and low temperature test chamber is precisely the core equipment for accomplishing this task.   The home environment is not always warm and pleasant, and products will face various harsh challenges in actual use. This mainly includes regional climate differences, ranging from the severe cold in Northeast China (below -30°C) to the scorching heat in Hainan (up to over 60°C in the car or on the balcony). High-temperature scenarios such as kitchens close to stoves, balconies exposed to direct sunlight, and stuffy attics, etc. Or low-temperature scenarios: warehouses/balconies without heating in northern winters, or near the freezer of refrigerators. The high and low temperature test chamber, by simulating these conditions, "accelerates" the aging of products in the laboratory and exposes problems in advance.   The actual test cases mainly cover the following aspects: 1. The smart TV was continuously operated at a high temperature of 55°C for 8 hours to test its heat dissipation design and prevent screen flickering and system freezing caused by overheating of the mainboard. 2. For products with lithium batteries (such as cordless vacuum cleaners and power tools), conduct charge and discharge cycles at -10°C to assess the battery performance and safety at low temperatures and prevent over-discharge or fire risks. 3. The air purifier (with both types of "environmental product" attributes) undergoes dozens of temperature cycles between -20°C and 45°C to ensure that its plastic air ducts, motor fixing frames and other structures will not crack or produce abnormal noises due to repeated thermal expansion and contraction. 4. Smart door lock: High-temperature and high-humidity test (such as 40°C, 93%RH) to prevent internal circuits from getting damp and short-circuited, which could lead to fingerprint recognition failure or the motor being unable to drive the lock tongue.   High and low temperature test chambers are not only applicable but also indispensable for the testing of household environmental products. By precisely controlling temperature conditions, it can ensure user safety and prevent the risk of fire or electric shock caused by overheating or short circuits. Ensure that the product can work stably in different climates and home environments to reduce after-sales malfunctions. And it can predict the service life of the product through accelerated testing. Therefore, both traditional home appliance giants and emerging smart home companies will take high and low temperature testing as a standard step in their product development and quality control processes.
    ЧИТАТЬ ДАЛЕЕ
  • Принцип выравнивания температуры внутри испытательной камеры с помощью воздушного клапана
    Sep 22, 2025
    Его основной принцип – замкнутая система с отрицательной обратной связью «нагрев – измерение – управление». Проще говоря, она заключается в точном регулировании мощности нагревательных элементов внутри бокса для компенсации рассеивания тепла, вызванного внешней средой, тем самым поддерживая постоянную температуру испытания, превышающую температуру окружающей среды. Процесс стабилизации температуры воздушным клапаном представляет собой динамический и непрерывно регулируемый замкнутый контур: Сначала задайте заданную температуру. Датчик температуры измеряет фактическую температуру внутри контейнера в режиме реального времени и передаёт сигнал на ПИД-регулятор.Когда ПИД-регулятор вычисляет значение ошибки, он рассчитывает мощность нагрева, которую необходимо скорректировать, на основе значения ошибки с помощью ПИД-алгоритма. Алгоритм учитывает три фактора:P (пропорция): Какова величина текущей погрешности? Чем больше погрешность, тем больше диапазон регулировки мощности нагрева.I (интеграл): накопление ошибок за определённый период времени. Используется для устранения статических ошибок (например, если всегда присутствует небольшое отклонение, интегральный член постепенно увеличивает мощность до полного его устранения).D (дифференциал): скорость изменения текущей погрешности. Если температура быстро приближается к заданному значению, мощность нагрева будет заранее снижена, чтобы предотвратить «перерегулирование».3. ПИД-регулятор посылает рассчитанный сигнал на регулятор мощности нагревательного элемента (например, твердотельное реле SSR), который точно регулирует напряжение или ток, подаваемый на нагревательный провод, тем самым управляя его тепловыделением.4. Вентилятор непрерывно работает, обеспечивая быстрое и равномерное распределение тепла, генерируемого системой отопления. Кроме того, он оперативно передаёт изменения сигнала датчика температуры на контроллер, что обеспечивает более оперативную реакцию системы. Балансир воздушного клапана измеряет объём воздуха, при этом плотность воздуха меняется в зависимости от температуры. При одном и том же значении перепада давления массовый или объёмный расход воздуха, соответствующий разной плотности, различается. Поэтому температура должна быть стабилизирована на известном фиксированном значении, чтобы микропроцессор прибора мог точно рассчитать объём воздуха при стандартных условиях на основе измеренного значения перепада давления по заданной формуле. Нестабильная температура может привести к ненадёжным результатам измерений.
    ЧИТАТЬ ДАЛЕЕ
  • Создание безопасной испытательной среды в испытательной камере
    Sep 16, 2025
    Ключ к созданию безопасной среды тестирования в лаборатории испытательная камера для высоких и низких температур заключается в обеспечении личной безопасности, безопасности оборудования, безопасности образцов для испытаний и точности данных.1.Меры личной безопасностиПеред открытием дверцы высокотемпературной камеры для извлечения образца необходимо надеть средства индивидуальной защиты, устойчивые к высоким и низким температурам. При выполнении операций, которые могут привести к разбрызгиванию или утечке очень горячих/холодных газов, рекомендуется надевать защитную маску или очки.Испытательную камеру следует устанавливать в хорошо проветриваемой лаборатории. Не допускается работа в замкнутом пространстве. Высокотемпературные испытания могут привести к выделению летучих веществ из образца. Хорошая вентиляция может предотвратить накопление вредных газов.Убедитесь, что характеристики кабеля питания соответствуют требованиям оборудования, а заземляющий провод надёжно подключён. Самое главное: категорически запрещается прикасаться к вилкам, выключателям и образцам мокрыми руками во избежание поражения электрическим током. 2. Установите оборудование правильно.Минимальное безопасное расстояние, указанное производителем (обычно не менее 50–100 см), должно быть соблюдено сзади, сверху и с обеих сторон оборудования для обеспечения нормальной работы конденсатора, компрессора и других систем отвода тепла. Плохая вентиляция может привести к перегреву оборудования, снижению производительности и даже возгоранию.Рекомендуется предусмотреть отдельную линию электропитания для испытательной камеры, чтобы избежать использования одной цепи с другим мощным оборудованием (например, кондиционерами и крупными приборами), что может вызвать колебания напряжения или отключение.Рекомендуемая температура окружающей среды для эксплуатации оборудования составляет от 5°C до 30°C. Чрезмерно высокая температура окружающей среды значительно увеличит нагрузку на компрессор, что приведет к снижению эффективности охлаждения и сбоям в работе. Обратите внимание, что оборудование не следует устанавливать под прямыми солнечными лучами, вблизи источников тепла или в местах с сильной вибрацией. 3. Обеспечение валидности и повторяемости тестовОбразцы следует размещать в центре рабочей камеры бокса. Между образцами, а также между образцами и стенкой бокса должно быть достаточно свободного пространства (обычно рекомендуется более 50 мм) для обеспечения беспрепятственной циркуляции воздуха внутри бокса и поддержания равномерной и стабильной температуры.После проведения испытаний в условиях высокой температуры и высокой влажности (например, в камере с постоянной температурой и влажностью), если требуются испытания при низкой температуре, следует провести операции по осушению, чтобы предотвратить чрезмерное образование льда внутри камеры, которое может повлиять на производительность оборудования.Категорически запрещается проводить испытания легковоспламеняющихся, взрывоопасных, сильнокоррозионных и легколетучих веществ, за исключением специально предназначенных для этого взрывобезопасных испытательных камер. Категорически запрещается размещать опасные грузы, такие как спирт и бензин, в обычных высоко- и низкотемпературных камерах. 4. Технические условия безопасной эксплуатации и аварийные процедурыПеред началом работы проверьте герметичность дверцы бокса и исправность замка. Убедитесь, что бокс чистый и без посторонних предметов. Убедитесь, что заданная температурная кривая (программа) верна.В период испытаний необходимо регулярно проверять, нормально ли работает оборудование, нет ли посторонних шумов и сигналов тревоги.Правила обращения с образцами и их размещения: Используйте перчатки, защищающие от высоких и низких температур. После открытия дверцы слегка повернитесь набок, чтобы избежать воздействия высокой температуры на лицо. Быстро и осторожно извлеките образец и поместите его в безопасное место.Действия в чрезвычайных ситуациях: ознакомьтесь с расположением кнопки аварийной остановки оборудования и способами быстрого отключения основного электропитания в случае чрезвычайной ситуации. Вместо водяных или пенных огнетушителей рядом должны находиться углекислотные огнетушители (подходящие для тушения пожаров, связанных с электропроводкой).
    ЧИТАТЬ ДАЛЕЕ
  • Руководство по испытаниям в лабораторной камере с тремя комбинациями для испытаний при низком давлении
    Sep 13, 2025
    Основная система трехкомбинационная испытательная камера В состав системы входят, главным образом, испытательная камера, вакуумная система, специальная система контроля температуры и влажности, а также высокоточный коллаборативный контроллер. По сути, это сложный комплекс оборудования, объединяющий в себе камеру для измерения температуры и влажности, вибростенд и вакуумную систему (с высокой степенью имитации). Процесс проведения испытаний при низком давлении представляет собой высокоточный процесс коллаборативного управления. На примере испытания при низкой температуре и низком давлении процесс испытания выглядит следующим образом: 1. Подготовка: прочно закрепите образец на поверхности вибростола внутри бокса (если вибрация не требуется, установите его на стойку для образцов), закройте и заблокируйте дверцу бокса, чтобы обеспечить эффективность высокопрочной уплотнительной ленты. Настройте полную программу испытаний на интерфейсе управления, включая: кривые давления, температуры, влажности и вибрации.2. Вакуумирование и охлаждение: система управления запускает вакуумный насос, и вакуумный клапан открывается, начиная откачку воздуха из контейнера. Тем временем система охлаждения начинает работать, подавая холодный воздух в контейнер, и температура начинает падать. Система управления динамически координирует скорость откачки вакуумного насоса и мощность холодильной системы. Поскольку при разрежении воздуха эффективность теплопередачи значительно снижается, и охлаждение становится сложнее. Система может не полностью остыть, пока давление воздуха не упадет до определенного уровня.3. Этап поддержания низкого давления/низкой температуры: как только давление и температура достигают заданных значений, система переходит в режим поддержания. Поскольку в любом из отсеков имеется крайне малая утечка, датчик давления отслеживает давление воздуха в режиме реального времени. Когда давление воздуха превышает заданное значение, вакуумный насос автоматически начинает откачивать воздух, поддерживая давление в очень точном диапазоне.4. Увлажнение — самый сложный этап. При необходимости имитации высокой влажности в условиях высокогорья и низкого давления система управления активирует внешний парогенератор и медленно «закачивает» полученный пар в камеру низкого давления через специальный клапан наддува и дозирования, а датчик влажности обеспечивает обратную связь.5. После окончания испытания система переходит в стадию восстановления. Контроллер медленно открывает клапан сброса давления или клапан подачи воздуха, чтобы в бокс медленно поступал сухой отфильтрованный воздух, что позволяет давлению постепенно вернуться к нормальному. Когда давление и температура воздуха стабилизируются на уровне комнатной температуры и нормального давления, контроллер подаст сигнал об окончании испытания. После этого оператор может открыть дверцу бокса и извлечь образец для последующего тестирования и оценки его эксплуатационных характеристик. Испытание низким давлением в трёхкомбинационной испытательной камере — это чрезвычайно сложный процесс, основанный на точном взаимодействии её герметичной камеры, мощной вакуумной системы и системы контроля температуры и влажности, специально разработанной для условий низкого давления. Она позволяет по-настоящему имитировать суровые испытания, которым подвергаются изделия одновременно в условиях высокогорья, высокогорья и других условиях, включая сильный холод, низкое содержание кислорода (низкое давление воздуха) и влажность. Это незаменимое испытательное оборудование в таких областях, как аэрокосмическая, военная промышленность и автомобильная электроника.
    ЧИТАТЬ ДАЛЕЕ
  • Как выбрать подходящий метод охлаждения для испытательных камер?
    Sep 09, 2025
    Воздушное и водяное охлаждение — два основных метода отвода тепла в холодильном оборудовании. Наиболее фундаментальное различие между ними заключается в разных средах, используемых для отвода тепла, вырабатываемого системой, во внешнюю среду: воздушное охлаждение использует воздух, а водяное — воду. Это ключевое различие привело к появлению множества различий между ними с точки зрения монтажа, эксплуатации, стоимости и сфер применения. 1. Система воздушного охлажденияПринцип работы системы воздушного охлаждения заключается в принудительном обдуве вентилятором основного теплорассеивающего элемента – оребрённого конденсатора. Система отводит тепло от конденсатора и рассеивает его в окружающем воздухе. Монтаж системы очень прост и гибок. Оборудование работает от сети, не требуя дополнительных вспомогательных сооружений, что минимизирует требования к реконструкции помещения. Эффективность охлаждения существенно зависит от температуры окружающей среды. В жаркое лето или в условиях высокой температуры и плохой вентиляции из-за уменьшения разницы температур между воздухом и конденсатором эффективность теплоотвода значительно снижается, что приводит к снижению холодопроизводительности оборудования и увеличению энергопотребления. Кроме того, при работе вентилятора наблюдается значительный шум. Первоначальные инвестиции обычно невелики, а ежедневное обслуживание относительно простое. Основная задача – регулярная очистка от пыли ребер конденсатора для обеспечения бесперебойной вентиляции. Основные эксплуатационные расходы – это электроэнергия. Системы с воздушным охлаждением отлично подходят для оборудования малого и среднего размера, районов с обильным электроснабжением, но скудными водными ресурсами или затрудненным доступом к воде, лабораторий с контролируемой температурой окружающей среды, а также проектов с ограниченным бюджетом или тех, где требуется простой и быстрый процесс установки. 2. Система водяного охлажденияПринцип работы системы водяного охлаждения заключается в использовании циркулирующей воды, протекающей через специальный конденсатор с водяным охлаждением, для поглощения и отвода тепла системы. Нагретый поток воды обычно транспортируется к наружной градирне для охлаждения, а затем снова используется. Ее монтаж сложен и требует полного набора внешних систем водоснабжения, включая градирни, водяные насосы, водопроводные сети и устройства очистки воды. Это не только определяет место установки оборудования, но и предъявляет высокие требования к планировке участка и инфраструктуре. Эффективность рассеивания тепла системы очень стабильна и практически не зависит от изменений внешней температуры окружающей среды. При этом рабочий шум вблизи корпуса оборудования относительно низок. Ее первоначальные инвестиции высоки. Помимо потребления электроэнергии, существуют и другие расходы, такие как постоянное потребление водных ресурсов во время ежедневной эксплуатации. Работы по техническому обслуживанию также более профессиональны и сложны, и необходимо предотвращать образование накипи, коррозию и рост микроорганизмов. Системы с водяным охлаждением в основном подходят для крупного мощного промышленного оборудования, цехов с высокими температурами окружающей среды или плохими условиями вентиляции, а также в ситуациях, когда требуются чрезвычайно высокая температурная стабильность и эффективность охлаждения. Выбор между воздушным и водяным охлаждением заключается не в оценке их абсолютного превосходства или неполноценности, а в поиске решения, наилучшим образом соответствующего конкретным условиям. Решения должны основываться на следующих соображениях: Во-первых, крупное мощное оборудование обычно предпочитает водяное охлаждение для достижения стабильной работы. В то же время необходимо оценить географический климат лаборатории (жаркий ли он), условия водоснабжения, пространство для установки и условия вентиляции. Во-вторых, если оцениваются относительно небольшие первоначальные инвестиции, воздушное охлаждение является подходящим выбором. Если основное внимание уделяется долгосрочной энергоэффективности и стабильности работы, и относительно высокая первоначальная стоимость строительства не смущает, то водяное охлаждение имеет больше преимуществ. Наконец, необходимо учесть, есть ли у вас профессиональные навыки проведения регулярного обслуживания сложных систем водоснабжения.
    ЧИТАТЬ ДАЛЕЕ
1 2 3 4 5 6
В общей сложности 6страницы

оставить сообщение

оставить сообщение
Если вы заинтересованы в нашей продукции и хотите узнать более подробную информацию, пожалуйста, оставьте сообщение здесь, мы ответим вам, как только сможем.
представлять на рассмотрение

Дом

Продукты

WhatsApp

связаться с нами